SUNT4-2 亮黄灯问题——9b2ccd5d-41ba-e584-b471-8fb634a6feac

9b2ccd5d-41ba-e584-b471-8fb634a6feac   -------------该号码在ilom里的open problems 里有这个错误号。

Hi **
   感谢您的更新和支持。我已经检查了您上传的explorer和snapshot。
Action Plan:
    这是一个已知问题,Bug ID是17452623,对于 Solaris10的补丁还没有发布,所以目前的解决办法是
1 清除FMA
2 Disable internal usb port.
  禁用该internal usb port不会对系统有影响,
If disable the ilomconfig-interconnect service, what is it function & impact?
A3) Very little impact as the Doc states " Note: Oracle Hardware Management Pack uses this interconnect but, if not available, it will use a slower, 

alternate path." 

Workaround

1). Clear the fault using fmadm repair in Solaris. This should automatically also clear the fault on the SP.
>  fmadm repair 9b2ccd5d-41ba-e584-b471-8fb634a6feac
2) Disable the following service:
# svcadm disable svc:/network/ilomconfig-interconnect:default  
It can take a couple of minutes until "ilomconfig list interconnect" shows it to be disabled. 

For more information, please refer to USB faults seen on T3 or T4 platforms during boot of Operating System (Doc ID 1566851.1) 
请使用浏览器的分享功能分享到微信等