IBM P570 更换风扇过程
前提:停止应用再操作
1 查看错误日志
通过命令查看错误
LABEL: SCAN_ERROR_CHRP
IDENTIFIER: BFE4C025
Date/Time: Sun Apr 18 11:22:48 BEIST 2010
Sequence Number: 12788
Machine Id: 00CBF25C4C00
Node Id: sbdata1
Class: H (表明硬件级故障)
Type: PERM (表明是永久性的故障)
Resource Name: sysplanar0
Resource Class: planar
Resource Type: sysplanar_rspc
Location:
Description
UNDETERMINED ERROR
Failure Causes
UNDETERMINED
Recommended Actions
RUN SYSTEM DIAGNOSTICS.
Detail Data
PROBLEM DATA
0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000
0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000
0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000
Diagnostic Analysis
Diagnostic Log sequence number: 10261
Resource tested: sysplanar0
Resource Description: System Planar
Location:
SRC: 11007610
Description: Power/Cooling subsystem Unrecovered Error, bypassed
with loss of redundancy. Refer to the system service
documentation for more information.
Additional Words: 2-003C0003 3-00000000 4-00000000 5-00000000
6-00000000 7-00000000 8-00000000 9-00000000
Possible FRUs:
Priority: L FRU: 53P5070 S/N: n/a CCIN: 6B0C
Location: U7879.001.DQD104K-A1
Priority: L FRU: 03N6603 S/N: YL11C6132304 CCIN: 28EA
Location: U7879.001.DQDKKWT-P1-C8
---------------------------------------------------------------------------
表明风扇坏掉。
2 确认坏件位置
由于P570有三个柜子,每一个柜子里都有FAN。如何确认在那一个柜子里呢?
查看errpt 以后可以看到
Possible FRUs:
Priority: L FRU: 53P5070 S/N: n/a CCIN: 6B0C
Location: U7879.001.DQD104K-A1
Priority: L FRU: 03N6603 S/N: YL11C6132304 CCIN: 28EA
Location: U7879.001.DQDKKWT-P1-C8
打开柜子的前面盖板,在柜子的右边上面有一条码上面就有SN号:DQD104K。表明就是这个柜子,如果不是,请再看其它几个柜子。
如图:
Location: U7879.001.DQD104K-A1中的A1表明是:A1风扇,一般有两个:A1与A2。
If the first 4 characters of the
9 character firmware release number are SF22 (SF22xxxxx), the control panel can be serviced with the
system power on. If the first 4 characters of the 9 character firmware release number are SF21
(SF21xxxxx), the control panel must be serviced with the system power off.
3 从HMC控制台或者HMC口进入ASMI菜单
选择左侧的Concurrent maintenance —— Control panel,在右侧的选项里选择Remove and click 点击继续,点击保存并退出,这样就给控制面板下电了。
4 再选择左侧的Concurrent maintenance-- IDE Device Control,选择Power off,这样就给光驱下电
5 更换过程
了解设备中的部件分布情况:
确定这次需要更换风扇的部件在什么位置。(I/O BLOWERS)
Location: U7879.001.DQD104K-A1
A1报错,表明A1风扇需要更换。
(1) 拔下操作面板
(2) 拔下DVD_ROM
(3) 拔下风扇
更换回去的流程相反操作,选换好风扇,再换回DVD—ROM、与控制面板。
6.安装光驱和液晶面板,并进入ASMI菜单,选择 Concurrent Maintenance,将光驱状态选择为power on,将液晶面板选为install 并保存退出
7.查看液晶面板和光驱是否可以重新工作。
Errpt 查看系统有无报错
6 测试、消除告警
更换完成以后,先清除日志
#errclear 0
然后再诊断一次。
#diag
查看一下,是否还有报错信息。
#再清除面板上的黄灯,
#/usr/lpp/diag*/bin/usysfault -s normal